Medical Policies - DME


Powered Exoskeleton for Ambulation in Patients With Lower-Limb Disabilities

Number:DME103.008

Effective Date:07-01-2018

Coverage:

*CAREFULLY CHECK STATE REGULATIONS AND/OR THE MEMBER CONTRACT*

Use of a powered exoskeleton for ambulation in patients with lower-limb disabilities is considered experimental, investigational and/or unproven.

Description:

An exoskeleton is an external structure with joints and links that that might be regarded as wearable robots designed around the shape and function of the human body. A powered exoskeleton, as described in this policy, consists of an exoskeleton-like framework worn by a person that includes a power source supplying energy for limb movement. The goal of the powered exoskeleton is to enable people who do not have volitional movement of their lower extremities to bear weight fully while standing, to ambulate over ground, and to ascend and descend stairs. The devices have the potential to restore mobility, increase function, and improve the health status and quality of life for wheelchair-bound patients. Some of the potential secondary health benefits associated with increased mobility include strength and cardiovascular health, decreased spasticity, improved bladder and bowel function, and psychosocial health. In addition to individuals with spinal cord injury, the powered exoskeleton might be used by patients with multiple sclerosis, amyotrophic lateral sclerosis, Guillain-Barré syndrome, and spina bifida.

One type of powered lower-limb exoskeleton (e.g., ReWalk, Indego) provides user-initiated mobility based on postural information. Standing, walking, sitting, and stair up/down modes are determined by a mode selector on a wristband. ReWalk includes an array of sensors and proprietary algorithms that analyze body movements (e.g., tilt of the torso) and manipulate the motorized leg braces. The tilt sensor is used to signal the onboard computer when to take the next step. Patients using the powered exoskeleton must be able to use their hands and shoulders with forearm crutches or a walker to maintain balance. Instructions for ambulating with the ReWalk (1) are to place the crutches ahead of the body, and then bend the elbows slightly, shifting weight towards the front leg, leaning towards the front leg side. The rear leg will lift slightly off of the ground and then begin to move forward. Using the crutches to straighten up will enable the rear leg to continue moving forward. The process is then repeated with the other leg.

To move from a seated to standing position or vice versa, the desired movement is selected by the mode selector on the wrist. There is a 5-second delay to allow the individual to shift weight (forward for sit-to-stand and slightly backward for stand-to-sit) and to place their crutches in the correct position. If the user is not in an appropriate position, a safety mechanism will be triggered. Walking can only be enabled while standing, and the weight shift must be sufficient to move the tilt sensor and to offload the back leg to allow it to swing forward. Continuous ambulation is accomplished by uninterrupted shifting onto the contralateral leg. The device can be switched to standing either via the mode selector or by not shifting weight laterally for 2 seconds, which triggers the safety mechanism to stop walking. Some patients have become proficient with ReWalk by the third week of training. (2)

Powered exoskeleton systems that use posture control and are being evaluated for home use include:

The Ekso™ GT robotic exoskeleton (Ekso Bionics) is available institutionally for rehabilitation. It is undergoing testing for personal use for ambulation in several registered trials.

The Indego® powered exoskeleton (also known as the Vanderbilt exoskeleton; Parker Hannifin) is used for gait training and is now available for home use. It includes functional electrical stimulation and weighs 26 pounds.

ReWalk (ReWalk Robotics) consists of an onboard computer, sensor array, and the rechargeable batteries that power the exoskeleton, which are contained in a backpack. The complete ReWalk system weighs about 16 kg (35 lb).

The X1 Mina Exoskeleton is a joint project of NASA Johnson Space Center and the Florida Institute for Human and Machine Cognition. It is being developed to provide mobility for both abled and disabled users, for rehabilitation, and exercise. It weighs 26 kg (57 lb).

Powered exoskeleton systems that use joystick control and are being evaluated for home use include:

REX® (REX Bionics) is designed for rehabilitation centers and hospitals. REX® P is designed for personal use and does not require use of crutches or a walker for stability, leaving the user hands-free.

WPAL (Wearable Power-Assist Locomotor; Fugita Health University) is designed for use with a custom walker.

HAL (Hybrid Assistive Limb).

Phoenix (suitX).

Regulatory Status

In 2014, ReWalk™ (ReWalk Robotics, previously Argo Medical Technologies) was granted a de novo 510(k) classification (K131798) by the U.S. Food and Drug Administration (FDA) (class II; FDA product code: PHL). The new classification applies to this device and substantially equivalent devices of this generic type. ReWalk™ device is the first external, powered, motorized orthosis (powered exoskeleton) used for medical purposes that is placed over a person’s paralyzed or weakened limbs for the purpose of providing ambulation. De novo classification allows novel products with moderate- or low-risk profiles and without predicates that would ordinarily require premarket approval as a class III device to be down-classified in an expedited manner and brought to market with a special control as a class II device.

The ReWalk™ is intended to enable individuals with spinal cord injury at levels T7 to L5 to perform ambulatory functions with supervision of a specially trained companion in accordance with the user assessment and training certification program. The device is also intended to enable individuals with spinal cord injury at levels T4 to T6 to perform ambulatory functions in rehabilitation institutions in accordance with the user assessment and training certification program. The ReWalk™ is not intended for sports or stair climbing.

Candidates for the device should have the following characteristics:

Hands and shoulders can support crutches or a walker;

Healthy bone density;

Skeleton does not suffer from any fractures;

Able to stand using a device such as a standing frame;

In general good health;

Height is between 160 cm and 190 cm (5'3"-6'2");

Weight does not exceed 100 kg (220 lb).

The FDA is requiring ReWalk’s manufacturer to complete a postmarket clinical study (PS14001) that will consist of a registry to collect data on adverse events related to the use of the ReWalk™ device and prospectively and systematically assess the adequacy of its training program.

In 2016, Indego® (Parker Hannifin) was cleared for marketing by the FDA through the 510(k) process (K152416). The FDA determined that this device was substantially equivalent to existing devices, citing ReWalk™ as a predicate device. Indego® is “intended to enable individuals with spinal cord injury at levels T7 to L5 to perform ambulatory functions with supervision of a specially trained companion”. Indego® has also received marketing clearance for use in rehabilitation institutions.

Ekso Bionics submitted an application in December 2014 for home use of the Ekso™ GT robotic exoskeleton. The exoskeleton is currently indicated for ambulatory functions in rehabilitation institutions (K143690).

FDA product code: PHL.

Rationale:

This policy was created in 2015 and has been updated periodically with searches of the MEDLINE database. The most recent literature update was performed through January 8, 2018.

Evidence reviews assess the clinical evidence to determine whether the use of a technology improves the net health outcome. Broadly defined, health outcomes are length of life, quality of life, and ability to function-including benefits and harms. Every clinical condition has specific outcomes that are important to patients and to managing the course of that condition. Validated outcome measures are necessary to ascertain whether a condition improves or worsens; and whether the magnitude of that change is clinically significant. The net health outcome is a balance of benefits and harms.

To assess whether the evidence is sufficient to draw conclusions about the net health outcome of a technology, 2 domains are examined: the relevance and the quality and credibility. To be relevant, studies must represent one or more intended clinical use of the technology in the intended population and compare an effective and appropriate alternative at a comparable intensity. For some conditions, the alternative will be supportive care or surveillance. The quality and credibility of the evidence depend on study design and conduct, minimizing bias and confounding that can generate incorrect findings. The randomized controlled trial is preferred to assess efficacy; however, in some circumstances, nonrandomized studies may be adequate. Randomized controlled trials are rarely large enough or long enough to capture less common adverse events and long-term effects. Other types of studies can be used for these purposes and to assess generalizability to broader clinical populations and settings of clinical practice.

Pre-post study designs (patient as their own control) are most likely to provide evidence on the effects of a powered exoskeleton on health outcomes. Outcomes of interest are the safety of the device, the effect of the exoskeleton on the ability to ambulate, and the downstream effect of ambulation on other health outcomes (e.g., bowel and bladder function, spasticity, and cardiovascular health). Of importance in this severely disabled population is the impact of this technology on activities of daily living, which can promote independence and improved quality of life.

Issues that need to be addressed include the device’s performance over the longer term when walking compared to wheelchair mobility, the user’s usual locomotion outside of the laboratory setting, and the use of different exoskeletons or the training context. (3) Adverse events (e.g., falling, tripping) can impact both safety and psychological security, and also need to be assessed.

Powered Exoskeleton for Ambulation

ReWalk

There is limited information about the use of ReWalk outside of the institutional setting. Several small series have been identified for ReWalk in an institutional setting. Standard measures of walking function include the Timed Up & Go test, which assesses the time required to get up from a chair and commence walking, the 10-meter walk test (10MWT), which evaluates the time required to walk 10 meters, and the 6- minute walk test (6MWT), which measures the distance walked in 6 minutes.

Included in the device application to the U.S. Food and Drug Administration was a multicenter evaluation of performance with the ReWalk in 24 individuals with spinal cord injury (SCI). (4) Screening criteria included complete motor cervical (C7-C8) or thoracic (T1-T12) SCI; age between 18 and 55 years; regular use of a reciprocating gait orthosis, knee-ankle-foot orthosis, or standing device; height between 160 to 190 cm, and weight less than 100 kg. Study participants received 16 to 24 training sessions of 60 to 90 minutes duration over about 8 weeks. The primary outcome measures were the 10MWT and the 6MWT. Results for the 6MWT were available for 20 participants, who walked for a range of 0 to over 100 meters in 6 minutes. For the 10MWT, 22 of the 24 participants required between 10 to more than 100 seconds to walk 10 meters.

Esquenazi et al. (2012) published a safety and efficacy trial of the ReWalk in 12 subjects with motor complete thoracic SCI. (5) All had lower-limb bone and joint integrity, adequate joint range of motion, and a history of standing (either with lower-limb bracing or a standing frame) on a frequent basis. Over 8 weeks, subjects received up to 24 sessions of training lasting 60 to 90 minutes per session that included stepping, sit-to-stand, standing, and stand-to-sit transfers. During this time, unsupervised use of the exoskeleton was not allowed. All 12 participants completed training and were able to independently transfer and walk for at least 50 to 100 meters for a period of at least 5 to 10 minutes. Participants did occasionally lose their balance and either caught themselves with their crutches or were stabilized by the physical therapist. With monitoring of walking, there were no serious adverse events such as falls, bone fractures, or episodes of autonomic dysreflexia. Self-reported health benefits collected at the end of training from 11 subjects included improved spasticity (n=3) and bowel regulation (n=5).

A report by Zeilig et al. (2012) described a pilot study of the ReWalk in 6 patients with SCIs. (1) Study participants required an average of 13.7 training sessions, each lasting an average of 50 minutes, before they were able to complete the Timed Up and Go test, 10MWT, and 6MWT. The average distance walked in 6 minutes was 47 meters, which highly correlated with the level of the SCI. There were no falls, skin or joint injuries during testing, and following training, subjects reported that they felt safe and comfortable using the device. Blood pressure and pulse rate were within the range consistent with physical activity.

Asselin et al. (2016) from the Department of Veterans Affairs reported on screening criteria, fitting, and training procedures for use of a powered exoskeleton. (6) Skills practiced included standing, sitting, standing balance, progression with both indoor and outdoor walking, and tasks that included reaching, stopping, turning, and door/threshold navigation. Training sessions were conducted for 60 to 90 minutes, 3 times a week, with at least 60 training sessions per patient.

A prerequisite for safe and independent home and community exoskeleton use, is that users are able to perform basic and advanced exoskeleton skills. While basic skills (e.g., sit-to-stand, stand-to-sit, and walking) are highly relevant for use in a clinical setting, more advanced skills (e.g., arresting gait on command, passing door thresholds, low curbs and ramps and controlling the input device) are required for safe independent community use. In 2017, Dijsseldonk et al. attempted to develop and test the hierarchy and reliability of a framework for measuring the progress in the ability to perform basic and advanced skills. (7) Twelve participants with paraplegia were given twenty-four training sessions in 8 weeks with the ReWalk exoskeleton. During the 2nd, 4th, and 6th training week the intermediate-skills-test was performed consisting of 27 skills, measured in a hierarchical order of difficulty, until two skills were not achieved. When participants could walk independently, the final-skills-test, consisting of 20 skills, was performed in the last training session. Each skill was performed at least two times with a maximum of three attempts. As a reliability measure the consistency was used, which was the number of skills performed the same in the first two attempts relative to the total number. Ten participants completed the training program.

Post-hocanalysis revealed a significant increase in the median achieved intermediate skills from 4 at the first to 10.5 at the third intermediate-skills-test. The rate of participants who achieved the intermediate skills decreased and the coefficient of reproducibility was 0.98. Eight participants met the criteria to perform the final-skills-test. Their median number of successfully performed final skills was 16.5 and 17 skills in the first and second time. The overall consistency of >70% was achieved in the intermediate-skills-test (73%) and the final-skills-test (81%). Eight out of twelve participants experienced skin damage during the training, in four participants this resulted in missed training sessions. Authors concluded that the hierarchical ordered skills test could discriminate across participants’ skill level, and that the overall consistency of the performed exoskeleton skills was considered acceptable. However, the skills tests proposed in this framework were based on independent performance of exoskeleton skills, but did not take the quality of the performance into consideration. For future research, the quality of how a skill is performed might be of interest in addition to whether it is possible to perform a skill independent. Moreover, all exoskeleton skills in this study were assessed in a clinical setting and it remains unknown which skills are relevant and which skill level is necessary for safe community use. Therefore, future research should focus on community use of an exoskeleton and its relation to the skill level during the training period measured with the proposed framework. (7)

Indego

As noted, a key question is whether a powered exoskeleton can be used independently and safely outside of the investigational setting. The Indego powered exoskeleton was evaluated after 5 training sessions (lasting 1.5 hours each for 5 consecutive days) in 16 patients with SCI between C5 and L1. (8) Testing included the 6MWT and 10MWT. Following training, patients with motor complete tetraplegia (C5-C7 injury level) were able to ambulate on indoor surfaces (hard flooring, carpet, and thresholds), outdoor surfaces (sidewalks), elevators, and ramps, using a walker with assistance from 1 or 2 therapists. In the group of patients with upper paraplegia (T1-T8 injury level) all were able to walk on indoor surfaces, outdoor surfaces, and in elevators; and most were successfully tested on ramps. Among the 8 patients with lower paraplegia (T9-L1 injury level), 6 were able to walk without assistance and 2 required minimal assistance from a therapist. Six were able to ambulate on indoor surfaces, outdoor surfaces, elevators, ramps, and grass, and 2 required minimal assistance from a therapist. No studies were identified that evaluated the Indego for distances beyond 10 meters.

Summary of Evidence

For individuals who have lower-limb disabilities who receive a powered exoskeleton, the evidence includes small case series. Relevant outcomes are functional outcomes, quality of life, and treatment-related mobility. At the present, evaluation of exoskeletons is limited to small studies performed in institutional settings with patients who have spinal cord injury. These studies have assessed the user’s ability to perform, under close supervision, standard tasks such as the Timed Up and Go test, 6-minute walk test, and 10-meter walk test. A 2016 report from the Veterans Administration has suggested that over 60 training sessions may be needed to achieve proficiency with both indoor and outdoor mobility, including door/threshold navigation, stopping, turning, and reaching. There are concerns about users’ safety with these devices under regular conditions, including the potential to trip and fall. Further study is needed to determine whether these devices can be successfully used outside of the institutional setting. The evidence is insufficient to determine the effects of the technology on health outcomes.

Ongoing and Unpublished Clinical Trials

Some currently unpublished trials that might influence this policy are listed in Table 1.

Table 1. Summary of Key Trials

NCT No.

Trial Name

Planned Enrollment

Completion Date

Ongoing

NCT01701388

Investigational Study of the Ekso Powered Exoskeleton for Ambulation in Individuals With Spinal Cord Injury (or Similar Neurological Weakness)

40

Dec 2017

(ongoing)

NCT03082898

Mobility and Therapeutic Benefits Resulting From Exoskeleton Use in a Clinical Setting (SC140121 Study 1)

24

Jun 2020

NCT02658656

Exoskeleton Assisted-Walking in Persons With SCI: Impact on Quality of Life

160

Aug 2020

Unpublished

NCT02202538a

Indego® Exoskeleton; Assessing Mobility for Persons With Spinal Cord Injury (SCI).

45

Oct 2015

(completed)

NCT: national clinical trial

a Denotes industry-sponsored or cosponsored trial.

Practice Guidelines and Position Statements

No guidelines or statements were identified.

Contract:

Each benefit plan, summary plan description or contract defines which services are covered, which services are excluded, and which services are subject to dollar caps or other limitations, conditions or exclusions. Members and their providers have the responsibility for consulting the member's benefit plan, summary plan description or contract to determine if there are any exclusions or other benefit limitations applicable to this service or supply. If there is a discrepancy between a Medical Policy and a member's benefit plan, summary plan description or contract, the benefit plan, summary plan description or contract will govern.

Coding:

There is no specific code for powered exoskeleton devices. An unlisted HCPCS code (e.g., E1399) would likely be reported.

CODING:

Disclaimer for coding information on Medical Policies

Procedure and diagnosis codes on Medical Policy documents are included only as a general reference tool for each policy. They may not be all-inclusive.

The presence or absence of procedure, service, supply, device or diagnosis codes in a Medical Policy document has no relevance for determination of benefit coverage for members or reimbursement for providers. Only the written coverage position in a medical policy should be used for such determinations.

Benefit coverage determinations based on written Medical Policy coverage positions must include review of the member’s benefit contract or Summary Plan Description (SPD) for defined coverage vs. non-coverage, benefit exclusions, and benefit limitations such as dollar or duration caps.

CPT/HCPCS/ICD-9/ICD-10 Codes

The following codes may be applicable to this Medical policy and may not be all inclusive.

CPT Codes

None

HCPCS Codes

E1399, L2999

ICD-9 Diagnosis Codes

Refer to the ICD-9-CM manual

ICD-9 Procedure Codes

Refer to the ICD-9-CM manual

ICD-10 Diagnosis Codes

Refer to the ICD-10-CM manual

ICD-10 Procedure Codes

Refer to the ICD-10-CM manual


Medicare Coverage:

The information contained in this section is for informational purposes only. HCSC makes no representation as to the accuracy of this information. It is not to be used for claims adjudication for HCSC Plans.

The Centers for Medicare and Medicaid Services (CMS) does not have a national Medicare coverage position. Coverage may be subject to local carrier discretion.

A national coverage position for Medicare may have been developed since this medical policy document was written. See Medicare's National Coverage at <http://www.cms.hhs.gov>.

References:

1. Zeilig G, Weingarden H, Zwecker M, et al. Safety and tolerance of the ReWalk exoskeleton suit for ambulation by people with complete spinal cord injury: a pilot study. J Spinal Cord Med. Mar 2012; 35(2):96-101. PMID 22333043

2. Asselin P, Knezevic S, Kornfeld S, et al. Heart rate and oxygen demand of powered exoskeleton-assisted walking in persons with paraplegia. J Rehabil Res Dev. 2015; 52(2):147-158. PMID 26230182

3. Lajeunesse V, Vincent C, Routhier F, et al. Exoskeletons' design and usefulness evidence according to a systematic review of lower limb exoskeletons used for functional mobility by people with spinal cord injury. Disabil Rehabil Assist Technol. Sep 4 2015:1-13. PMID 26340538

4. U.S. Food and Drug Administration (FDA). Evaluation of automatic class III designation (de novo) for Argo ReWalk (2014). Available at <http://www.accessdata.fda.gov> (accessed – 2018 February 26).

5. Esquenazi A, Talaty M, Packel A, et al. The ReWalk powered exoskeleton to restore ambulatory function to individuals with thoracic-level motor-complete spinal cord injury. Am J Phys Med Rehabil. Nov 2012; 91(11):911- 921. PMID 23085703

6. Asselin PK, Avedissian M, Knezevic S, et al. Training persons with spinal cord injury to ambulate using a powered exoskeleton. J Vis Exp. Jun 16 2016(112). PMID 27340808

7. Dijsseldonk R, Rijken H, van Nes I, et al. A framework for measuring the progress in exoskeleton skills in people with complete spinal cord injury. Front Neurosci. 2017; 11:699. PMID 29311780

8. Hartigan C, Kandilakis C, Dalley S, et al. Mobility outcomes following five training sessions with a powered exoskeleton. Top Spinal Cord Inj Rehabil. Spring 2015; 21(2):93-99. PMID 26364278

9. Powered Exoskeleton for Ambulation in Patients With Lower-Limb Disabilities. Chicago, Illinois: Blue Cross Blue Shield Association Medical Policy Reference Manual (March 2018) Durable Medical Equipment 1.03.04.

Policy History:

Date Reason
7/1/2018 Document updated with literature review Coverage unchanged. Reference 6-7 added.
7/15/2017 Reviewed. No changes.
7/1/2016 Document updated with literature review. Coverage unchanged.
11/1/2015 New medical document. Use of a powered exoskeleton for ambulation in patients with lower-limb disabilities is considered experimental, investigational and/or unproven.

Archived Document(s):